Styrodur® 3000 CS

Description:

The innovative universal thermal insulation board:

  • With smooth surface and rabbet
  • Suitable for nearly all building construction and civil engineering applications
  • Consistent insulating properties across all board thicknesses

Primary application recommendations:

Perimeter insulation floor, floor insulation, attic insulation, core insulation, flat roof insulation, inverted roof, frost protection for road construction, artificial ice rink, steep roof insulation

More Less

For detailed information see our brochure technical data

Technical data

Property Unit Code according to EN 13164 3000 CS Standard
Edge profile -
Surface - skin
Length x width mm 1265 x 615

Thermal
conductivity

Thermal
resistance

[W/(m•K)]

[m2•K/W]

 

λD

RD

EN
13164
Thickness 30 mm - 0,033 0,90  
40 mm - 0,033 1,20
50 mm - 0,033 1,50
60 mm - 0,033 1,80
80 mm - 0,033 2,40
100 mm - 0,033 3,00
120 mm - 0,033 3,60
140 mm - 0,033 4,20
160 mm - 0,033 4,80
180 mm - 0,033 5,45
200 mm - 0,033 6,05
240 mm1) - 0,033 6,85
Compressive stress or
compressive strength
at 10 % deformation
kPa CS(10\Y) 300 EN
826
Compressive creep over 50 years < 2 % deformation kPa CC(2/1,5/50) 110 EN
1606
Dimensional stability:
70 °C; 90 % r.F.
% DS(70,90) ≤ 5 % EN
1604
Deformation behavior
load 40 kPa; 70 °C
% DLT(2)5 ≤ 5 % EN
1605
Linear coefficient of
thermal expansion
Longitudinal
Transverse
mm/(m•K)
 
-
-
0,08
0,06
DIN
53752
Reaction to fire Euroclass - E EN
13501-1
Long-term water absorption by immersion Vol.-% WL(T)0,7 < 0,7 EN
12087
Long-term water absorption by diffusion Vol.-% WD(V)3 < 3 EN
12088
Water-vapor
transmission
(thickness-dependent)
- MU 150 - 80 EN
12086
Freeze-thaw
resistance
Vol.-% FTCD ≤ 1 EN
12091
Maximum service
temperature
°C - 75 EN
14706

1) on request

Where can Styrodur® be obtained?

To the Distribution Partners


Back to the Overview